Test |
Test Method |
DenLine |
Dupont |
Hydrostatic Pressure |
AATCC 127-194 |
189 mbar |
112 mbar |
Breathablity (MVTR) |
ASSTM E96 |
5,100 |
3,960 |
Particle Holdout |
Nelson Lab |
100% |
88.4% |
Lint particles shed during abrasion (>0.5 micron) |
INDA 160.1-92 |
770 |
1,840 |
AntiStatic |
ASTM D257 |
<1010 |
<1010 |
Blood Penetration |
ASTM F1670 |
Pass |
Fail |
Viral Penetration |
ASTM F1671 |
Pass |
Fail |
Tensile Strength (MD) |
ASTM D5034 |
23.4 lbs. |
24.2 lbs. |
Tensile Strength (CD) |
ASTM D5034 |
16.2 lbs. |
17.5 lbs. |